Quick Estimation of Salinity in Field Soils and Irrigation Water with LandMapper ERM-02
Soil salinity is routinely evaluated in the labs from electrical conductivity of liquid soil saturation extract (ECe). The resulted total salinity is reported either directly in conductivity units (dS/m) or converted to TDS (total dissolved solids) concentration in ppm (parts per million) using formula: 1 dS/m = 1 mS/cm = 1 mmho/cm = 640 ppm = 640 mg/L= 0.64 g/L=0.064%
But now EC of soil and waters can be measured directly in the field using highly accurate method of four-electrode probe and Landmapper ERM-02 measuring device. Best of all, probes can be build to sense different soil layers down to 30 ft! Probes are simple and inexpensive to make from common materials available at any hardware store.
Salinity Class
|
Electrical Conductivity, ECw (dS/m=mS/cm=mmho/cm)
|
Total dissolved solids, TDS (ppm)
|
Nonsaline water |
<0.7
|
<500
|
Saline water |
0.7-42
|
500-30,000
|
Slightly saline
|
0.7-3
|
500-2000
|
Medium saline
|
3-6
|
2000-4000
|
Highly saline
|
6-14
|
4000-9000
|
Very highly saline
|
14-42
|
9000-30,000
|
Brine |
>42
|
>30,0000
|

Bulk soil electrical conductivity (ECa) is measured from soil surface to the depth in the big soil volume determined by the distance among four electrodes (ABMN) and therefore is more representative of field conditions than measurements in small soil sample or soil ECa insertion probe. The depth and volume of measurement may be varied by changing the spacing between electrodes. When the distance between the outside pair of electrodes (the current electrodes, AB) is small, the flow of electricity is shallower. The effective depth of measurement is about one-third of the distance between AB electrodes. The calculation of ECa from field measurements done with different size probes will be done automatically by LandMapper ERM-02 if geometrical coefficient Kg is set in device for specific probe. Kg can be calculated from distances among ABMN electrodes using formula below (input distances in meters):

If you need help with mapping soil salinity, please, do not hesitate to contact Landviser, LLC - post comment, email info@landviser.com, or call 609-412-0555.
- Блог пользователя landviser
- Войдите или зарегистрируйтесь, чтобы получить возможность отправлять комментарии
check this great website for
check this great website for irrigation related guides ...
h2oirrigation.ae
please do check it out....
thank you for sharing this
thank you for sharing this
I want to subscribe to your
I want to subscribe to your site updates delivered via email. How to do that?
If you register on this site
If you register on this site you will be automatically subscribed to the all new content, usually 1-3 new pages a week. As a registered user you can also tweak your subscription, to receive a weekly digest of posts or subscribe to blogs only or to specific keywords/pages.