Application of Geophysical Methods to Evaluate Hydrology and Soil Properties in Urban Areas
Submitted by landviser on Tue, 05/14/2013 - 17:39- Login or register to post comments
- Google Scholar
- BibTex
- RIS
Groundwater Investigation in Kuala Selangor Using Vertical Electrical Sounding (ves) Surveys
Submitted by landviser on Tue, 05/14/2013 - 17:39- Login or register to post comments
- Google Scholar
- BibTex
- RIS
A Vertical Electrical Sounding Method for Agricultural Soil Survey
Submitted by landviser on Tue, 05/14/2013 - 17:38- Login or register to post comments
- Google Scholar
- BibTex
- RIS
A Vertical Electrical Sounding and Self-Potential Methods to Survey for Placement of Potable Water Wells
Submitted by landviser on Tue, 05/14/2013 - 17:38- Login or register to post comments
- Google Scholar
- BibTex
- RIS
Using LandMapper to Monitor Soil Salinity and Mitigate Its Effects on Rice Production at US Gulf Coast
Submitted by landviser on Tue, 05/14/2013 - 17:38Full text in PDF format is available for registered users @ http://www.landviser.net/webfm_send/94
- Login or register to post comments
- Google Scholar
- BibTex
- RIS
Vertical Electrical Sounding to detect peat deposit thickness and drying depth
Submitted by landviser on Tue, 08/07/2012 - 15:17The valley landscapes of humid areas are dominated with peat soils of various origins, which become the most productive soils after the proper drainage and cultivation. The high fertility and proximity to water make peat soils the most desirable for vegetable production. However, these soils are also subject to quick degradation during agricultural usage. Excess drainage increases the unproductive decomposition and mineralization of peat and can cause spontaneous ignition of peat soils, whereas little or no drainage can be non-sufficient for normal agricultural practices. Therefore, drainage design and the following agriculture practice on peat soils should be based on careful studies of the peat soil genesis and hydrology of the areas.
Method VES is suitable for detection the resistivity in different soil and geological strata without digging or boring. Usually, peat shows not much difference in electrical properties along the profile. Water content of cultivated peat soils is close to the field capacity during the whole growing season.
- landviser's blog
- Login or register to post comments
- Read more
Electrical geophysical methods to outline ground water rising in urban areas
Submitted by landviser on Mon, 06/18/2012 - 16:54The groundwater table rises steadily in the delta Volga, where Astrakhan’ city is located because of irrigation and rising of the Caspian Sea level. The highly saline groundwater enhances secondary salinity in the area. The groundwater caused visible destruction of more than 20% of the buildings in Astrakhan’ city. Natural hazardous groundwater condition in delta Volga was further aggravated in the urban areas by the uncontrolled leakage from the canals and plumbing pipes.
The methods of vertical electrical sounding (VES) and non-contact electromagnetic profiling (NEP) were tested in 1995 for detail outlining of the groundwater table within the representative part of Astrakhan’ city. The study area was located in the center of Astrakhan’ with a large change of elevation, which induced a high variation of groundwater table within the area.
Profiles of alluvial soils in delta Volga consist of thin layers of silt, clay, and sand. However, only water and salt content distributions within the soil profile cause considerable differentiation of the electrical resistivity in these soils. The soil profile can be generally divided into the top unsaturated layer with high resistivity and the bottom layer saturated by saline groundwater with low resistivity. Considering high distinction in electrical resistivity between unsaturated and saturated zones, the VES method was applied for detection of groundwater table. With the 1-D computer interpretation of the VES data the transition between top layer with high resistivity and bottom layer with low resistivity (i.e. groundwater table) was determined accurately. Compared with the groundwater tables measured in wells, the relative errors of the VES estimation were from 3 to 13%.
Vertical Electrical Sounding to Detect Groundwater Levels in Arid Areas
Submitted by landviser on Thu, 05/24/2012 - 20:53Water and salt content distributions within the soil profile are the main properties causing considerable variations in electrical resistivity. In arid areas, the water content and salt distributions are determined mainly by the saline groundwater, rather then by precipitation.
The soil profile is divided into a top unsaturated layer with high resistivity and a bottom layer saturated by saline groundwater with low resistivity. Considering large differences in electrical resistivity between the unsaturated and saturated zones, the VES method was applied to detect the saline groundwater level.